SQP Series Vane Pump

SQP series intra-vane pump having high pressure and low sound are developed to meet the application of industry. Total 4 series and 34 sizes are available. Intra-vane design enables the pump having high pressure...

Products Specifications:

Vane Pump in Series SQP

■General Description
SQP series intra-vane pump having high pressure and low sound are developed to meet the application of industry. Total 4 series and 34 sizes are available. Intra-vane design enables the pump having high pressure, large capacity, compact size, low sound level and longer service life features, its main technical data have reached to the advanced level of the same product in the world.

With complete specifications, reliable performance, reasonable construction and convenient installation and easy maintenance, it is widely used in hydraulic systems for machine-tools pressure, die casting machines, engineering,plastic injection moulding and other machineries.Main characteristics:
1.The pump cartridge of SQP can change with that of Vickers series intra-vane pump.
2.It can replace the pump cartridge to change displacement.
3.Strengthened pump housing design offers a better anti-vibration ability,which effect the remarkable low noise.

■  SQP Series Single Pump

▲  Model Code

1. F3—Viton seals  Omit if not required
2. SQP1—Series designation
    SQP1—7.5~45ml/r     SQP2—33~67ml/r
    SQP3—81~121ml/r     SQP4—138~237ml/r
3. 12—Displacement code

Series

Displacement code

SQP1

2  3  4  5  6  7  8  9  10  11  12  14

SQP2

10  12  14  15  17  19  21

SQP3

25  30  32  35  38

SQP4

42  45  50  57  60  66  75

Rated capacity in USgpm at 1200rpm and 0.7MPa
4. A—SAE4 bolt flange
    M—Metric thread
    I—Inch thread
5. F—Mounting and shaft seal assembly
    S—Flange mount and doubles haft seal
    Omit for flange mounting with single shaft seal
    F—Foot mounting
6. 1—Shaft type
    1—1Straight keyed(Standard)
    86—86 Straight keyed(Heavy duty)
    11—Splined(Not available on SQP1)
    151—Splined(For SQP1 only)
7. A—Outlet positions (Viewed from cover end of pump)
    A—Opposite inlet port
    B— 90°CCW from inlet
    C—Inlet with inlet
    D—90°CW from inlet
8. R—Rotation (Viewed from shaft end of pump)
    R—Right hand for clockwise,omit
    L—Left hand for counterclockwise
9.10—Design number

▲  Technical Data

Series designation

Code

Geometric
displacement

Min.
speed
(rpm)

Using antiwear hydraulic oil or phosphate ester fluid

Sound levels at 13.8 MPa,26cSt and 50°C

 

 

Weight
(kg)

ml/r

in3/r

Max.speed
(rpm)

Max.operating
Pressure (MPa)

1200
(rpm)

1500
(rpm)

1800
(rpm)

SQP1

2

7.5

0.46

600

1800

14

62

64

65

16

3

10

0.61

4

13

0.79

 

17.5

5

18

1.01

6

19

1.16

7

23

1.40

8

27

1.67

9

30

1.85

10

32

1.95

11

36

2.20

12

40

2.44

16

14

45

2.78

14

SQP2

10

33

1.98

600

1800

17.2

63

64

65

25

12

39

2.38

14

45

2.78

15

47

2.89

17

55

3.36

19

60

3.66

21

67

4.13

SQP3

25

81

4.94

600

1800

17.2

64

68

69

35

30

97

5.91

32

101

6.16

35

112

6.83

38

121

7.37

SQP4

42

138

8.41

600

1800

17.2

67

70

73

59.5

45

147

8.95

50

162

9.85

57

181

11.05

60

193

11.75

66

212

12.93

75

237

14.46

1. The max. pressure of using water glycol fluid is the same as antiwear hydraulic oil or phosphate ester fluid and the max. speed is 1200rpm. 

2. The max. pressure of using the water-oil emulsions is 13.8MPa and the max. speed is 1200rpm.

▲  Configuration and Installation Dimension(mm)

★SQP1 ★SQP2 ★SQP3

       

Model

A

B

ØC

D

E

ØG

H

J

L

M

ØN

SQP1

30.1

22.2

19.1

47.6

13

31.8

140

58.7

102.1

32.9

101.6

SQP2

35.7

26.2

25.4

52.4

16

38.1

160

69.9

120.6

38.1

127

SQP3

42.8

30.1

31.8

58.7

16

50.8

180

77.7

125.5

38.1

127 


P

Q

S

T

ØV

W

ØX

ØF×Full thread depth

ØK×Full thread depth

9.5

154

76.2

146.1

14.2

174

140

4-3/8-16UNC-2B Deep 19.1

4-7/16-14UNC-2B Deep 21.6

9.5

182

81

181

17.5

213

162

4-3/8-16UNC-2B Deep 19.1

4-1/2-13UNC-2B Deep 23.8

9.5

211

91

181

17.5

213

183

4-7/16-14UNC-2B Deep 21.6

4-1/2-13UNC-2B Deep 23.9


★SQP4

       

■  SQP Series Double Pump 


▲  Model Code

 

F3—Viton seals  Omit if not required
2. SQP21—Series

 Series

 Geometric displacement(ml/r)

Shaft end

Cover end

SQP21

33~67

7.5~45

SQP31

33~67

33~67

SQP32

81~121

7.5~45

SQP41

81~121

33~67

SQP42

138~237

7.5~45

SQP43

138~237

33~67

3. 21—Displacement code-shaft end pump

Series

Displacement Code

SQP2*

10  12  14  15  17  19  21

SQP3*

25  30  35  38

SQP4*

42  45  50  57  60  66  75

4. 8—Displacement code-cover end pump

Series

Displacement Code

SQP*1

2  3  4  5  6  7  8  9  10  11  12  14

SQP*2

10  12  14  15  17  19  21

SQP*3

25  30  32  35  38

5. A—SAE4 bolt flange
    M—Metric thread
    I—Inch thread
6. F—Mounting and shaft seal assembly
    S—Flange mount and doubles haft seal
    Omit for flange mounting with single shaft seal
    F—Foot mounting
7. 1—Shaft type
    1—Straight keyed(Standard)
    86—Straight keyed(Heavy duty)
    11—Splined
8. AA—Outlet port positions (Viewed from cover end of pump)

Outlet positions (All series except SQP43)

With No.1 outlet opposite inlet

AA

No.2 outlet 135°CCW from inlet

AB

No.2 outlet 45°CCW from inlet

AC

No.2 outlet 45°CW from inlet

AD

No.2 outlet 135°CW from inlet

With No.1 outlet 90°CCW from inlet

BA

No.2 outlet 135°CCW from inlet

BB

No.2 outlet 45°CCW from inlet

BC

No.2 outlet 45°CW from inlet

BD

No.2 outlet 135°CW from inlet

With No.1 outlet inline with inlet

CA

No.2 outlet 135°CCW from inlet

CB

No.2 outlet 45°CCW from inlet

CC

No.2 outlet 45°CW from inlet

CD

No.2 outlet 135°CW from inlet

With No.1 outlet 90°CW from inlet

DA

No.2 outlet 135°CCW from inlet

DB

No.2 outlet 45°CCW from inlet

DC

No.2 outlet 45°CW from inlet

DD

No.2 outlet 135°CW from inlet

 

 Outlet positions  (Series SQP43)

 

With No.1 outlet opposite inlet

AA

No.2 outlet opposite inlet

AB

No.2 outlet 90°CCW from inlet

AC

No.2 outlet inlet with inlet

AD

No.2 outlet 90°CW from inlet

With No.1 outlet 90°CCW from inlet

BA

No.2 outlet opposite inlet

BB

No.2 outlet 90°CCW from inlet

BC

No.2 outlet inlet with inlet

BD

No.2 outlet 90°CW from inlet

With No.1 outlet
inline with inlet

CA

No.2 outlet opposite inlet

CB

No.2 outlet 90°CCW from inlet

CC

No.2 outlet inlet with inlet

CD

No.2 outlet 90°CW from inlet

With No.1 outlet 90°CW from inlet

DA

No.2 outlet opposite inlet

DB

No.2 outlet 90°CCW from inlet

DC

No.2 outlet inlet with inlet

DD

No.2 outlet 90°CW from inlet

9. R—Rotation (Viewed from shaft)
    R—Right hand for clockwise,omit
    L—Left hand for counterclock wise
10. 10—Design number

 Configuration and Installation Dimension(mm)

★SQP21 ★SQP31 ★SQP32

     

Model

A

B

C

ØD

E

ØF

G

ØH

J

ØK

ØL

M

SQP21

50.8

26.2

16

25.4

52.4

127

9.5

63.5

88.9

19.1

17.5

76.2

SQP31

61.9

30.1

16

31.8

58.7

127

9.5

76.2

106.3

19.1

17.5

76.2

SQP32

61.9

30.1

16

31.8

58.7

127

9.5

76.2

106.3

25.4

17.5

80

 

N

P

Q

R

S

T

U

ØV

X

Y

Z

88

101.6

38.1

81

269

84.1

181

160

213

22.2

47.6

99.5

114.4

38.1

91.5

293

90.5

181

180

213

22.2

47.6

109.5

114.4

38.1

91.5

310

90.5

181

180

213

26.2

52.4

 

Inlet port flange connection

NO.1 outlet port flange connection

NO.2 outlet port flange connection

4-1/2-13UNC-2B Deep 23.8

4-3/8-16UNC-2B Deep 19.1

4-3/8-16UNC-2B Deep 19.1

4-5/8-11UNC-2B Deep 28.6

4-7/16-14UNC-2B Deep 21.6

4-3/8-16UNC-2B Deep 19.1

4-5/8-16UNC-2B Deep 28.6

4-7/16-14UNC-2B Deep 21.6

4-3/8-16UNC-2B Deep 19.1

★SQP4*

    

See P10 to know the position of SQP43's outlet

Model

A

B

C

ØD

E

ØF

G

ØH

J

ØK

ØL

M

SQP41

69.9

35.7

22

38.1

69.9

152.4

12.7

88.9

120.7

19.1

23

76.2

SQP42

69.9

35.7

22

38.1

69.9

152.4

12.7

88.9

120.7

25.4

23

80

SQP43

77.8

35.7

22

38.1

69.9

152.4

12.7

101.6

130.2

31.8

23

101.6

 

N

P

Q

R

S

T

U

X

Y

Z

119.9

119.3

42.9

139.7

323

115

228.6

273

22.2

47.6

135.8

119.3

42.9

139.7

346

115

228.6

273

26.2

52.4

148.4

133.3

42.9

139.7

371

115

228.6

273

30.1

58.7

 

Inlet port flange connection

NO.1 outlet port flange connection

NO.2 outlet port flange connection

4-5/8-11UNC-2B Deep 31.8

4-1/2-13UNC-2B Deep 23.8

4-3/8-16UNC-2B Deep 19.1

4-5/8-11UNC-2B Deep 31.8

4-1/2-13UNC-2B Deep 23.8

4-3/8-16UNC-2B Deep 19.1

4-5/8-11UNC-2B Deep 28.6

4-1/2-13UNC-2B Deep 23.8

4-7/16-14UNC-2B Deep 20.6

■  Shaft Type

★  Straight key shaft type

                  

Model

Shaft code

A

B

C

ØD

E

F(Key)width×length

SQP1

1

59

9.53

12.1

22.225
22.20

24.50
24.40

4.76×32

SQP2SQP21

1

59

9.53

11.1

22.225
22.20

24.50
24.40

4.76×32

86

78

9.53

11.1

25.375
25.350

28.30
28.10

6.36×50.8

SQP3SQP3*

1

73.2

9.53

11.1

31.75
31.70

35.36
35.10

7.94×38.1

86

86

9.53

11.1

34.9
34.87

38.60
38.30

7.94×54

SQP4SQP4*

1

62

12.7

14.22

31.75 31.70

35.36
35.10

7.94×28.5

86

87.4

12.7

14.22

38.07
38.05

42.40
42.10

9.54×50.8

★  Splined shaft type

Series

Shaft code

A

B

C

D

ØE

               Spline data reference

Number of teeth

Pitch

Major
diameter

Pitch
diameter 

Minor diameter

Suitable form

SQP1

151

41.1

9.53

11.1

3.9

27.8

13

16/32

21.8~21.6

20.64

18.16

Side fit

SQP2
SQP21

11

44.5

9.53

11.1

3.9

27.8

13

16/32

21.8~21.6

20.64

18.16

SQP3
SQP3*

11

58.7

9.53

11.1

6.35

35.1

14

12/24

31.2~31.1

29.63

26.99

SQP4
SQP4*

11

61.9

12.7

14.3

9.7

39.6

14

12/24

31.2~31.1

29.63

26.99

Installation and Application

1.Operating oil
①Anti-wear hydraulic oil is recommended. It's viscosity range: 10~100cSt(1.8-13°E),recommended viscosity 24cSt(50℃).
②Filtration: the filtration rating shouldn't be lower than 25μm, a filter with filtration rating of 70~150μm should be fitted at inlet port and its rated flow more than twice of that of the pump.
③Temperature range: ambient temperature -20~+70℃; operating temperature +10~+60℃.
④Fire resistance fluid: special seal should be used when using fire resistance fluid; for rated pressure and max. speed of the pump,refer to that in the main performance data table.

2.Installation
①Foot and frame for pump must be reliable, solid and good in vibration absorbance.
②Horizontal mounting is recommended to maintain necessary case fluid level. Concentricity of shafts between pump and motor is important to pump life and should be within Ø0.1mm.Radial or axial load can't be applied on pump shaft and a flexible coupling should be used and rigid linkage not permitted.
③To reduce noise and vibration of system caused by trapped air, attachment flange at inlet port, all fittings and pipelines must be strictly sealed.
④Before starting the pump, you should check if the inlet and outlet have been correctly connected and the rotation of the pump is in the line with the arrow in the nameplate. To prevent the pump from cavitation caused by the first starting or stopping run for a longer time, air should be bled from the pump delivery line. This may be accomplished by loosening a connection in the delivery line close to the pump. An air bleed valve is available for this purpose. When starting, the pump should be repeatedly jogged without any load. After the pump may normally run, it can be actually primed.
⑤Suction lift of pump shouldn't be higher than 500mm.

3.Replacing cartridge kit
The cartridge kit design of SQP series vane pumps offers fast and efficient field serviceability.
When replacing the cartridge kit, seals inside the pump should be checked to avoid them crimping;
when tightening the fastening screws, they should be treated with even force in diagonal direction.

 

With advanced equipment and qualified workers, Hislohydraulic.com is well-known as one of the professional China sqp series vane pump manufacturers. We have professional staff specialized in manufacturing high quality hydraulics in our factory. Welcome to wholesale high precision sqp series vane pump at cheap price with us.